  • Uses the world class compact V1000 Solar drive
  • Suitable for BLDC & PM Motors
  • Suitable for surface mount and submersible pumps with 3-phase induction motors
  • Wide range capacity from 0.1 KW to 18.5 KW
  • All day Run-Stop-Restart mode management
  • Diagnostics and self-protection features
  • Protection against dry run of pump
  • Simple and faster installation and Commissioning

V1000 Technical Specifications

Electrical Specification
Pump Inverter typeV/F control with Derived MPPT Technology
Dual Supply(GRID/Solar)Change over Available
Input DC Voltage(Voc)400 VDC for 200 Volts class and 800VDC for 400 Volts Class
Input DC Volts(Vmp)280 VDC to 310 VDC / 560 VDC to 620 VDC
Input DC Current and PowerAs per motor capacity
Min Frequency (Parameter)0Hz (selectable setting range 0 to 120HZ)
Max Frequency (Parameter)120Hz (selectable setting range 0 to 120Hz)
Shock10 to less than 20Hz (9.8 m/s^2) max.
Output AC Voltage3 Phase 190-240 V (-15%, +10%) /380-480 V (-15%, +10%)
Output AC CurrentAs per chart above
Motor Frequency0 – 60Hz
Motor control technologyV/f control
MPPT Voltage230 to 360 VDC for 200volts class, 460 to 620 VDC for 400volts class
Over Load capacity120% for ND
Under Voltage125VDC for 200volts class / 250 for 400 volts class
ProtectionDry Run, Short Circuit, Open Phase in Input and Output side, High Voltage, Low Voltage And Overload, Earthling and reverse polarity.
Ambient Temperature-10°C to + 50°C
Relative HumidityMax. 95% relative humidity
Testing & Regulatory Specifications
Testing standards Efficiency TestIEC61508 / CE/UL/cUL/RoHS
Remote monitoringPossible

Remote Monitoring

An Integrated , real time remote monitoring solution – used to collect , monitor, control, and analyze various operational parameters from VFD driven solar pumps which are installed in remote locations. All parameters and events are stored in the server database.